Wepụ-n'ime
Power stations, factory, sewers na data centers pour enormous amounts of heat into the air and water every day. Much of it could warm homes instead. Nearly none of it could make electricity. Here is why, and where recovery works.
Helen Ltd / Wikimedia Commons (CC BY-SA 3.0)
N’okpuru ebe obibi na Helsinki, n’ime ụlọ ndị e ji arụ ọrụ, a na-eji ọkụ dị ukwuu na-ekpo ọkụ site na mmiri mmiri nke obodo ahụ na-ewepụ ya na mmiri na-abịaghachite site na netwọk okpomọkụ ya, ma tinye ya na mpaghara okpomọkụ nke na-ekpo ọkụ ụlọ. Ụlọ ọrụ Katri Vala, nke a na-ahụ maka ụlọ ọrụ ike Helen, mepụtara 570,000 MWh nke ọkụ n’afọ 2017 site na nnukwu ọkụ ọkụ atọ, na nke ise, ejiri ya mee ihe na 2021, e chere na ọ ga-ebelata nke ahụ ruo 200,000 MWh kwa afọ; ikike ya ruru ihe dị ka 123 MW (Wikipedia, Energy in Finland, citing Helen, 2018). Ọnwụ ahụ nọ ebe ahụ. Ọ na-agafe n’ụsọ osimiri Baltic.
Ọtụtụ ndị na-asị na ọ bụ “ọnụ ụzọ nke ike” ka a na-echekwa ọkụ. A 2016 ọmụmụ na-atụle na 72% nke ụwa’s primary ike ehichapụ mgbe mgbanwe, n’ihi na okpomọkụ, na na 63% nke waste ọkụ streams bụ n’okpuru 100 ° C (Forman et al., 2016). Nke abụọ bụ nke dị mkpa. Ọtụtụ n’ime ihe ndị a na-eji eme ihe bụ ọkụ eletrik ma ọ bụ ike eletriki. Ihu a na-agwa gị ihe mere, nakwa ihe ọ ga-ewe iji jiri ya.
Gịnị bụ ya
Ọrụ nke ntụgharị bụ ịgbanwe ihe na-eme ka ihe dị iche iche dị na ya ma ọ bụ mepụta ihe ọhụrụ. Ọ nwere ụdị atọ:
- Iji n’ụzọ. Ọnụ mmiri ma ọ bụ gas site na ụlọ ọrụ, ebe ọkụ ma ọ bụ ọdụ ụgbọala ike ga-aga site na ihe eji emegharị okpomọkụ gaa na netwọk okpomọkụ mpaghara ma ọ bụ usoro ọzọ. Ọ bụ ya mere ọtụtụ ndị Denmark na Sweden ji malite netwọk okpomọkụ.
- Heat pumps on cool sources. Sewage, data centers, supermarkets, metro tunnels na mmiri okpomọkụ bụ naanị 10 ruo 40 °C. A na-eji ọkụ eletrik dị ala karịa nke a ga-eji n’ọtụtụ ebe, ya bụ, ọ na-ewepụta ihe ruru 60 ruo 90% nke ike eletriki.
- Ime ọkụ eletrik. Ọkụ na-apụ site n’ime kilns, furnaces na engines, nke dịkarịa ala 200 °C, nwere ike ịkwọ ụgbọala steam turbine ma ọ bụ organic Rankine cycle (ORC), a obere turbine nke na-eji fluid nke na-ekpo ọkụ na okpomọkụ dị ala karịa mmiri.

Otú ọ dị
Valu nke okpomọkụ ahaziela site na okpomọkụ ya. KWh otu nke okpomọkụ na 30 °C na kWh otu na 600 °C bụ ọnụọgụgụ dị iche iche nke ike mana ọ bụghị uru dị iche iche. Ọrụ nke Carnot, nke dị elu maka ọbụla engine na-atụgharị ọkụ n’ime ọrụ, bụ η = 1 − T_cold / T_hot, na okpomọkụ na kelvin. Na n’ime ime na 25 °C (298 K):
- okpomọkụ na 30 °C (303 K):
1 − 298/303 = 1.6% - okpomọkụ na 90 °C (363 K):
1 − 298/363 = 18% - okpomọkụ na 300 °C (573 K):
1 − 298/573 = 48%
Ụdị igwe dị eziokwu na-erughị n’elu nke abụọ nke ihe ndị a. Ọrụ Rankine, nhọrọ a na-ejikarị eme ihe maka ịnabata ike eletriki site na okpomọkụ dị ala, na-agbanwe 5 ruo 20% nke okpomọkụ, na-arị elu na okpomọkụ ya (Quoilin et al., 2013). N’okpuru 80 ° C, ịmepụta ọkụ eletrik adịghị mkpa maka akụrụngwa.

Heat pumps na-arụ ọrụ n’ụzọ ọzọ. Heat pump’s ceiling bụ COP = T_hot / (T_hot − T_cold): nke dị obere nke elu, nke dị ukwuu nke okpomọkụ kwa yunit nke eletriki. Na-ebuli 30 ° C data-n’etiti okpomọkụ ruo 80 ° C nwere Carnot COP nke ihe dịka 6.4; nnukwu ọkụ eletrik dị ukwuu na-eru nso n’elu, gburugburu 3. Yabụ 100 kWh nke 30 °C ọkụ na-apụ n’ọnụ ọnụ 45 kWh nke eletriki ga-abụ ihe dị ka 145 kWh nke ọkụ netwọk. Ọ bụghị ike eletriki a na-ewepụ: ọ ga-agwụkwa dịka ọkụ.
Oge dị nso bụ nkwụsị ọzọ. Ọkụ dị ọnụ ala ịkpụga ya. Ụlọ ọrụ ahụ na-arụpụta ihe dị iche iche, gụnyere ụgbọ ala, ụgbọ mmiri, na akụrụngwa eletriki. Ọnụọgụgụ nke okpomọkụ na-apụta mgbe onye ọrụ okpomọkụ nọ n’ebe dị nso na isi, ma ọ bụ mgbe netwọk okpomọkụ na-agagharị n’ihu ya. N’oge a, “ụdị nke anọ” netwọk na-arụ ọrụ na okpomọkụ dị ala (n’etiti 50 ruo 70 ° C) n’ụzọ ziri ezi ka ọ bụrụ na enwere ike iji ọkụ dị ala karịa (Lund et al., 2014).

Ọrụ bụ nke atọ. A data center na-eme ọkụ afọ niile; ụlọ chọrọ ọtụtụ ya n’oge okpomọkụ. Ntọala na-echekwa nke a site n’ịchekwa okpomọkụ, ndị ọzọ na-ebugharị ọkụ na, n’oge ọkọchị, site na ịkpụ ọkụ na-enweghị ike iji ya.

Ogo
- Temperature. Oge okpomọkụ nke ọbụla dị n’ime ya bụ ọkụ eletrik. Carnot equation abụghị ihe a ga-ahazi.
- Nkebi. Osisi dị nso n’ọbụla onyenweta okpomọkụ bụ nke na-enweghị uru, ọbụna ma ọ bụrụ na ọ buru ibu.
- Mismatch in time. Industrial na data-center okpomọkụ bụ nke dị n’otu; okpomọkụ chọrọ bụ oge na-erughị elu na ụtụtụ oyi.
- Ndị na-eguzosi ike n’ihe na ndị ọrụ. Ntọala agaghị adị n’okpuru ụlọọrụ nke nwere ike mechie ma ọ bụ ebe data nke nwere ike ịkpụga. Nkwekọrịta, ike nchekwa na ịkekọrịta nke ihe ize ndụ dị mkpa dịka injinia.
- Eziokwu mbụ. Ọnụọgụgụ nke ọkụ kacha mma bụ okpomọkụ a na-ewepụghị. Nhazi ka mma na sava dị ike na-ewepụ ihe dị n’aka iji weghachi, na nke ahụ bụ ihe ọma.
Ọrụ ọfụụ, ejirila ya mee ihe
| Pọ́ràèzì | Ebee, mgbe | Ebe obibi okpomọkụ nakwa ijeri | Ihe a na-ekwu |
|---|---|---|---|
| Katri Vala ọkụ na-ekpo ọkụ ụlọ ọrụ | Helsinki, Finland, kemgbe 2006, e mepere emepe kemgbe | Ọnụ mmiri na-agwọta mmiri na mpaghara mmiri na-ebuli elu, nnukwu ọkụ eletrik na rock caverns | 570,000 MWh nke okpomọkụ na 2017 site na ọkụ ọkụ atọ; nke ise site na 2021 na-eweta ruo 200,000 MWh kwa afọ; banyere 123 MW n’ozuzu (Helen, 2018; Wikipedia) |
| Meta Odense data center na Fjernvarme Fyn | Odense, Denmark, kemgbe 2020 | Nchedo sava a na-ewepụ site n’ihe ọkụ na-ekpo ọkụ n’ime netwọk obodo | Nlekọta: 100,000 MWh nke ọkụ n’afọ, dị ka ụlọ 6,900 (Meta, 2020) |
| Stockholm | Stockholm, Sweden, kemgbe 2017 | Stockholm Exergi na-azụta ọkụ site n’ebe data dị maka netwọk obodo ahụ | Program maka “a data center industry ebe ọbụla okpomọkụ a na-echekwa” (Stockholm Data Parks) |
| Northern European data centers | Finland, Sweden, Denmark, Norway | Nhazi | Data-ndụmọdụ ọkụ nwere ike ịkpuchi akụkụ dị mkpa nke mpaghara okpomọkụ na obodo Nordic ma ọ bụrụ na netwọk na ọnụahịa ga-enye (Wahlroos et al., 2018) |
Ụdị akara abụọ nke iwu na-egosi ebe ọ ga-aga. Germany ugbu a chọrọ data center ọhụrụ na-amalite ọrụ site na July 2026 iji jiri 10% nke ike ha, na-arị elu ruo 15% site na July 2027 na 20% site na July 2028, ma ọ bụrụ na nkwekọrịta netwọk ọkụ dị na ebe (Energieeffizienzgesetz, akụkụ 11). Na ebe nchekwa data na-eto ngwa ngwa: IEA na-atụ anya ha ga-eji ihe dịka 415 TWh nke ọkụ eletrik na 2024, n’akụkụ 1.5% nke ọkụ eletrik ụwa, na-aga n’ihu na-eru 945 TWh na 2030 (IEA, Energy and AI, 2025). Ozugbo ọ gasịrị, ọ na-apụta dị ka okpomọkụ dị ala.

Na Denmark, Finland na Sweden, ọkụ eletrik dị n’obodo na-enye nnukwu uru nke ahịa okpomọkụ, ya mere ha na-aga n’ihu na iji ọkụ ọkụ (Werner, 2017). Ebe ọbụla nke na-agaghị adị bụ netwọk, ọ bụghị okpomọkụ.
Ihe ọ na-efu
N’ihi na ọ bụghị ike eletrik, ya mere ebe a na-ahụ maka ebe (solar rooftop na ihe dịka $ 0.19 kwa kWh n’ime anyị Fan Wall model, n’ime Lazard nke June 2026 nke $0.09 to $ 0.20 maka ụlọ ọrụ rooftop solar) dị naanị maka obere ọnọdụ okpomọkụ dị elu na-eme ọkụ eletrik. Maka okpomọkụ, onye na-agbachitere bụ boiler gas. Site n’iji ọnụọgụ abụọ dị ka na ụdị nchekwa okpomọkụ anyị (gass wholesale na € 35 kwa MWh, carbon na € 70 kwa ton, 90% boiler), ọkụ gas dị ihe dịka 5 ruo 6 euro cents kwa kWh.

Ọkụ site na ala-temperature isi site na a nnukwu okpomọkụ pumps na-eri eletriki gbanwere site na COP, nakwa ngwaọrụ e mepụtara n’elu okpomọkụ ọ na-enye. Ọnụahịa e bipụtara maka nnukwu okpomọkụ na njikọta dị iche iche site na ebe, ya mere anyị na-egosi ọnụọgụ dịka ntụgharị (20 afọ, 7% nke ụgwọ nkwụghachi azụ, COP 3, pipes na njikọ anaghị etinye):
| Nchedo ọkụ na-echekwa ụgwọ kwa kW nke okpomọkụ | Electricity €50 per MWh, 3,000 hours a year | Elektrọníkì €50, 6,000 awa | Ike eletriki €100, 3,000 awa | Elektrọníkì €100, 6,000 awa |
|---|---|---|---|---|
| €500 | 3.2 c | 2.4 c | 4.9 c | 4.1 c |
| €1,000 | 4.8 c | 3.2 c | 6.5 c | 4.9 c |
| €1,500 | 6.4 c | 4.0 c | 8.1 c | 5.7 c |
Euro cents kwa kWh nke okpomọkụ. Our calculation: equipment cost × 0.0944 ÷ awa + eletriki price ÷ 3.
Ọtụtụ mgbe, ọkụ na-abịaghachi azụ bụ ihe dị mkpa n’ihi na ọ na-arụ ọrụ na gas n’oge okpomọkụ na-agba ọsọ ọtụtụ awa kwa afọ ma ọ bụ ebe a na-ebubata ya na netwọk. Ihe ndị dị ala bụ ihe ndị ahụ (ọnụọgụgụ ọhụrụ nke kilomita ole na ole nwere ike ịba uru karịa okpomọkụ) na ihe ize ndụ nke isi mmalite ga-ewepụ. Ọ bụrụ na a gaghị eji ọkụ eletrik eme ihe, ọ ga-abụrịrị na ọ bụ ike dị ala ka a ga-eji.

Ọ bụ ihe dị iche iche ime ọkụ eletrik site na okpomọkụ nke ọnwụ: otu ORC na-agba ọsọ naanị ebe okpomọkụ dị ọkụ, adịgide adịgide na n’efu, ma ọ bụ mgbe ahụ output ya bụ obere ma e jiri ya tụnyere okpomọkụ na-aga.
Ebe ọ ga-enwe ike ịlụ, na ebe ọ gaghị ekwe omume
Ihe ahụ nwere ike ịlụ:
- Ndị obodo nwere netwọk ọkụ n’ebe dị nso na ebe data, ọrụ mmiri ozuzo, sistemụ metro, ụlọ ahịa na ụlọ ọrụ.
- Industrial parks, ebe otu osisi na-ahapụ ọkụ bụ usoro ọkụ nke ọzọ.
- Ndị data center ọhụrụ ejirila site na mmalite mee ka mmiri dị ọkụ, ọkachasị na-ekpo ọkụ mmiri n’ụdị 40 ruo 60 °C.
- Industrieslọ ọrụ okpomọkụ dị elu (simenti, glaasi, ákwà mgbochi, kemịkalụ), ebe ihe na-apụ n’elu 250 °C nwere ike ịkwọ ụgbọala ORC ma ọ bụ steam turbine maka ọkụ eletrik, ma ọ bụ ihe ndị ọzọ.
- Ihe ọkụ mmiri ozuzo, nke bụ n’ụzọ dị irè, na-adị nso n’obodo ma na-enwe ike n’oge okpomọkụ.

Ọ gaghị abịa:
- Ndị ntọala nsochi anya na-enweghị onye ọrụ okpomọkụ n’ebe ahụ: ebe nchekwa data nke ọwụwa anyanwụ mọọbụ osisi emeredịkachọrọ.
- Imegharị ala-ụdị okpomọkụ n’ime eletriki. Na 30 ruo 60 °C Carnot ceiling bụ pasentị ole na ole; enweghị ngwaike na-agbanwe nke ahụ.
- Nkebi nke enweghị nrụọrụ weebụ okpomọkụ, ruo mgbe onye ọbụla mepụtara otu. Network, ọ bụghị okpomọkụ, bụ n’ozuzu ya inwe ego.
- N’ihi na ihe kpatara iji chebe usoroiheomume ndị a na-ahapụghị. Ọrụsi ike bụ nke mbụ.
Ihe bụ ihe e gosipụtara, dị n’aka na nke a na-atụ anya
Proven: ihe mgbochi Carnot na ike ọkụ na ike; n’okporo ụzọ dị ukwuu nke ikuku site na mmiri ozuzo na ebe nchekwa data gaa na mpaghara okpomọkụ na Helsinki, Odense na Stockholm; netwọk ọkụ ọkụ ụlọ ọrụ n’akụkụ Denmark na Sweden; ORC unit na-azọpụta eletriki site na ọkụ ọkụ ụlọ ọrụ.
Plausible: ọtụtụ ndị ọhụrụ data center na Europe na-enye ike dị mkpa, e nyere aka site na iwu dịka Germany; ala-ọnụ ọgụgụ netwọk nke na-ewe karịa ala-grade ike; mmiri-cooled servers na-enye 50 ruo 60 ° C mmiri nke chọrọ obere ma ọ bụ enweghị ike ọkụ.

Speculative: eletriki dị mkpa n’ụzọ akụ na ụba site na okpomọkụ n’okpuru 80 ° C; mgbake ọkụ n’ime obodo enweghị usoro netwọk; thermoelectric panels na-akwụ ụgwọ maka onwe ha.
Mepee ajụjụ ntinye
- Mapping. Ebee, n’ụdị okpomọkụ ole na ole nakwa n’ụdị ihe ole ka ọnwụ ọkụ dị, ma jikọta ya na ebe achọrọ ọkụ? Mepee, maps mpaghara bụ nke dị n’ebe ahụ.
- Nkwekọrịta na ọha na eze. Ònye ga-akwụ maka njikọ ahụ, nakwa ònye ga-eburu ọha na eze ma ọ bụrụ na isi mmalite mechie?
- Njekọlọtọ okpomọkụ dị ala. Olee otú ịgbanwe n’ebe ahụ nọ na-ekpo ọkụ nke ọma na netwọk nakwa ụlọ iji rụọ ọrụ dị mma.
- High-temperature heat pumps na-enye steam na 120 ruo 200 °C maka ụlọ ọrụ, site na okpomọkụ na 60 ruo 100 °C.
- Nchekwa oge opupu ihe ubi nke na-echekwa okpomọkụ data-ndụ maka oge oyi.
- Measured performance. Published yearly data on heat delivered, electricity used and costs for real projects.
Ihe ọbụla prototype na-arụ ọrụ ga-achọ
N’ihi ya, ọ bụ ihe dị mkpa ka ị gbanwee ha. Ihe ọhụrụ bara uru bụ n’ịkpọkọta isi mmalite na ndị ọrụ ọnụ, na-ekpo ọkụ okpomọkụ dị elu, na n’ịchịkwa. Ọrụ móòdù ga-enye ọkụ a na-emetụ n’aka onye ọrụ.
| Nhazi | Ọrụ | Nhọrọ ọ na-enye | Nri | Oge |
|---|---|---|---|---|
| 1. Nlekọta okpomọkụ | Kpọtụla n’ụdị na okpomọkụ nke ọbụna mmiri ozuzo maka izu ole na ole na-eji loggers; mapụ ndị ọrụ ọkụ n’ime 1 ruo 2 km | Ọ bụ na ọ dị ọkụ, n’ụdị okpomọkụ bara uru, nso nke ọma n’ojieme? | $5k to $20k | 1 ruo 3 ọnwa |
| 2. Bench demonstrator | A 10 ka 50 kW okpomọkụ exchanger na okpomọkụ pump on the n’ezie isi, na okpomọkụ na eletriki mita | COP a mụọla, n’okporo ụzọ nakwa n’ihe dị n’aka na okporo ụzọ | $30k to $150k | 6 ruo 12 ọnwa |
| 3. Ntọala njikọ | Ntọhapụ n’ime ụlọ ma ọ bụ netwọk obere, afọ nke data, nkwanye ugwu | Nri nke ọbụla kwa kWh nke okpomọkụ nakwa nkwekọrịta móòdù | $0.3M to $2M | 12 ruo 24 ọnwa |

Anyị chọrọ
- Ndị injinia ọkụ mpaghara na ndị ọrụ netwọk.
- Heat pump specialists, ọkachasị maka nnukwu na elu-ọsọ igwe.
- Data-center na ndị nlekọta ike ụlọ ọrụ chọrọ ịkekọrịta okpomọkụ na data mmiri.
- Urban planners na GIS analyzers ka map isi mmalite na ndị ọrụ.
- Ndị ọka iwu na ndị nchịkwa akụnụba iji mepụta ihe ọkụkụ nke na-echekwa ihe egwu dị mma.
- Process engineers maka fouling, corrosion na ịsacha nke exchangers okpomọkụ na dirty streams dị ka mmiri ozuzo na flue gas.
I nwere echiche ka mma?
Ndị otu ụfọdụ nke Foundation nwere ike inwe ndị enyi ga-anụ okwu banyere echiche dị ike gbasara ike. Ka a na-ewere ya, echiche chọrọ ọrụ, ndụ-ndụ model nke na-emepụta ike; maka echiche nrụzi ọkụ, nke ahụ pụtara ụdị nke na-enye ọkụ ma ọ bụ eletriki, na-apụta ya na iji ike ya onwe ya banye na ngwaọrụ, enweghị ike ịgwa. A na-anabatakwa echiche ndị dị n’akwụkwọ: ọ bụrụ na physics na ọnụọgụgụ bụ ihe siri ike, anyị nwere ike ịkpọpụta ha ebe a na weebụsaịtị. Ma ịzụta ego na-enweghị ọrụ model bụ ihe dị mfe, na ọ dịghị ihe ebe a bụ a nkwa nke ego, n’ihu ma ọ bụ introductions.
Ziga echiche gị site na n’ime usoro iheomume nkwalite na nsogbu ọ na-ewepụ, nyocha physics, ọnụọgụgụ nke dị ka kWh, nakwa nnwale dị ala nke nwere ike igosi ya na ọ bụ eziokwu. Ọ bụrụ na ị nwere model ọrụ, tinye ya n’ihe oyiyi nke a kpụgachara ya nakwa otú i si kpụga ya. ụdị isi mmalite ike peeji na-ewere nke a nakwa ndị ọzọ dị iche iche n’ihe ọmụma radar.
Ebe obibi
- Forman, C., Muritala, I.K., Pardemann, R. na Meyer, B. (2016). Nhazi nke ike okpomọkụ nke ụwa. Ndị na-agbagharị na ndị na-eguzogide ike n’ihe 57, 1568-1579.
- Helen (2018). Ndị na-emegharị ihe n’ime ụlọ ọhụrụ ga-ebugharịkwa ya na Helsinki; Wikipedia, Energy in Finland.
- Meta (2020). Odense data center: heat recovery.
- Data Parks Webụsaịtị usoroiheomume.
- Wahlroos, M., Pärssinen, M., Rinne, S., Syri, S. na Manner, J. (2018). N’ọdịnihu, echiche banyere iji ọkụ na-ekpo ọkụ: ihe gbasara nke data center na Northern Europe. Renewable na Sustainable Energy Review 82, 1749-1764.
- Quoilin, S., Van Den Broek, M., Declaye, S., Dewallef, P. na Lemort, V. (2013). Ọrụ a na-arụ bụ nyocha nke usoro Organic Rankine Cycle (ORC). Ndị na-agbagharị na ndị na-eguzogide ike n’ihe 22, 168-186.
- Lund, H., Werner, S., Wiltshire, R. na ndị ọzọ. (2014). 4th Generation District Heating (4GDH). Energy 68, 1-11.
- Werner, S. (2017). Nnyocha mba ụwa nke mpaghara okpomọkụ na okpomọkụ. Energy 137, 617-631.
- Germany (2023). Energieeffizienzgesetz (EnEfG), ngalaba 11: ebe nchekwa data.
- IEA (2025). Energy na AI.
- Lazard (June 2026). Levelized Cost of Energy+, version 19.
- Local Solar System Ụlọọrụ. The Fan Wall open model: ụlọ elu nke $0.19 kwa kWh.
- Wikipedia Amager Bakke: 157 ruo 247 MW nke ọkụ dị na mpaghara na ruo 63 MW nke ike eletrik site na ihe ndị a na-ewepụ n’ụlọ, na ski slope na roof.